Copper water easy kit for TRUMPF 1653112, 1653113, 1653114

Describe

Copper water treatment easy kit 3 for TRUMPF 1653112 1653112, 1653113, 1653114

For cleaning the cooling circuits and replacing the cooling water of Trumpf® laser systems.

Recommended for cleaning once a year. The water must be replaced after the process.

Copper water treatment easy kit 3 (for Trumpf laser cutting machine)

The Copper water treatment easy kit 3 is used for the treatment of circulating water used in copper circuit of Trumpf laser cutting machine .

The kit contain the followings.

  • Biocide
  • Inhibitor and
  • User instructions.
  • Equivalent to Part No. 1653112, 1653113, 1653114 RWK113/EZCU3NA

Copper water treatment easy kit 3 for TRUMPF 1653112 1653112, 1653113, 1653114

Prior to the process, check the interiors of the tank. If it is contaminated, then the cooling water must be drained off and the tanks must be cleaned. Afterwards, refill the tanks with demineralized water (at least 65%) before starting the process.

Process Steps:

  1. Pour the cleaning biocide into the used water in the tank.
  2. Perform the cleaning cycle for 2 hours. Production can continue while cleaning.
  3. Drain off all the water.
  4. Immediately after draining, flush the complete circuit with demineralized water. Keep doing so until the conductivity falls below 20 μS/cm after flushing.
  5. Close the stopcocks upstream and downstream from the filters and strainers, if present.
  6. Replace all filters in the cooling water circuits. Clean all strainers present.
  7. Open the stopcocks again, if present.
  8. Fill the tank completely to 100% capacity.
  9. Add all inhibitors from the bottles provided in the water treatment kit into the water tanks and circulate the water for a few minutes.
  10. Check the water conductivity & ensure the following limit values:
    • Copper cooling circuit: 200 μS/cm
    • Aluminum circuit: 500 μS/cm
  11. Log the cleaning date, time & measurements.

Dosage

Read the label on the Biocide & Inhibitor bottles and ensure the appropriate product and quantity according to the water tank capacity. However, for convenient handling, the bottle caps are labeled with the following colors:

  • Cleaning Biocide = RED
  • Copper corrosion control agent/inhibitor = Yellow
  • Aluminum corrosion control agent/inhibitor = Blue

Cooling Water Specification

For cooling, use only distilled, deionized, or demineralized water with the following specifications:

  • Specific conductivity: less than 10 μS/cm
  • Carbonate content: less than 100 mg/l

Contact infomation:

  • LECI Co., Ltd

  • R-1901, Saigon Trade Center Bld, 37 Ton Duc Thang Str., Ben Nghe W., Dist. 1, HCM City 70000, VN.

  • Long Bien, Ha Noi, VN.

  • Phone: 02822202988

  • Hotline:  (+84) 901442689

  • Website: lecilaser.com