OmniCure S2000 Elite - UV spot curing
- Trang chủ
- UV equipment
- OmniCure S2000 Elite - UV spot curing

The OmniCure S2000 Elite is a new generation lamp-based UV spot curing system designed and developed for the most demanding manufacturing applications. Offering highest reliability and quality for adhesive curing processes, the OmniCure S2000 Elite redefines UV spot curing with enhanced productivity, precision, and security, while enabling next level control and usability.
Offering a powerful 200 Watt lamp with a guaranteed life of 2000 hours, the OmniCure S2000 Elite also offers our proprietary Closed-Loop Feedback technology that monitors light output in real time and automatically corrects the light output within +/- 5% to ensure a consistent and repeatable process. The new 4.3” high resolution touch screen enhances ease of use by simplifying navigation
and access to system functionality. The all new StepCure 2.0 features with 7 programmable PLC output channels provide the power to easily configure cure profiles for even the most advanced workflows. When combined with the OmniCure R2000 Radiometer, the OmniCure S2000 UV spot curing system is unmatched in precision and reliability.
Part Number: 010-00464R, 010-00529R, 010-00530R, 10-00577R
S2000 Elite Bundles, Optional Filters, and New Accesories
Part Number | Description |
010-00464R | OmniCure S2000 Elite - System Only Lamp and optical bandpass filter not included, must be ordered separately. |
010-00529R | OmniCure S2000 Elite - 320-500 nm Includes 012-68000R Standard lamp and 320-500 nm optical bandpass filter cartridge. |
010-00530R | OmniCure S2000 Elite - Surface Cure Includes 012-69000R Surface Cure lamp and Blank optical bandpass filter cartridge |
010-00577R | OmniCure S2000 Elite - Legacy Replacement Kit Includes 012-68000R Standard lamp, 320-500 nm optical bandpass filter cartridge, and External PLC Adapter |
Accessories Description | |
019-00387R | S2000 Elite Filter 400-500 nm |
019-00388R | S2000 Elite Filter 365 nm |
019-00389R | S2000 Elite Filter 320-390 nm |
019-00390R | S2000 Elite Filter 250-450 nm |
019-00391R | S2000 Elite Filter 320-500 nm |
019-00392R | S2000 Elite Blank Filter |
019-00410R | S2000 Elite, Optical bandpass filter kit |
SR S2000 Elite Custom Filter options available under SR | |
019-00406R | S2000 Elite Intelli-Tap Supervisor NFC card |
019-00407R | S2000 Elite Intelli-Tap Admin NFC card |
019-00395R | S2000 to S2000 Elite External PLC adapter |
Technical Specifications:
Control & Repeatability | CLF | +/-5% or 200 mW/cm2, whichever is greater |
Calibration/ Radiometry (R2000) | Calibration/ Radiometry (R2000) | |
Intelli-Lamp | V 2.0 – Not compatible with older gen systems | |
High Speed Mechanical Shutter | YES (30 ms) | |
StepCure | StepCure 2.0 Can be programed on the System UI, Web UI, or loaded onto a SD card | |
Optical | Replacement Lamp Part No. | Standard: 012-68000R Surface Cure: 012-69000R |
Optical Output | Up to 37 W/cm2 | |
Optical Filters | User Interchangeable | |
Filter Selection | No filter, 250-400 nm, 320-390 nm, 320-500 nm, 365 nm, 400-500 nm Custom Filters available | |
Warm-up period | Min 4 min | |
Lamp Technology | High Pressure 200 Watt Mercury Vapor Short Arc with integrated Intelli-Lamp | |
Lamp Life | Guaranteed 2000 hours | |
User Interface | Manual Control | Built-in PLC controller with 7 programmable PLC output channels Fully programmable in new StepCure 2.0 |
Automation / Industry 4.0 Compatibility | USB Type B | |
RJ485 Ethernet Built-in server enables Web-GUI based monitoring and remote control | ||
SD Card Store/ Read StepCure profiles, System Log, Firmware Update | ||
Flight recorder | ||
NFC | ||
Field Upgradeable system software | ||
Electrical | Rated Input Voltage | 100-240VAC, 50/60Hz |
Current | 3.5A Max at 120VAC | |
2.0A Max at 240VAC | ||
Physical | Size (H x W x D) | 268 x 139 x 289 mm (10.54 x 5.45 x 11.38 in) |
Weight | 5 kg (11 lbs) | |
Rated Operating Temperature | 15°C to 40°C | |
Warranty | System | 1 Year |
Lamp Strike | 2000 Hours |
Contact infomation:
LECI Co., Ltd
R-1901, Saigon Trade Center Bld, 37 Ton Duc Thang Str., Ben Nghe W., Dist. 1, HCM City 70000, VN.
Long Bien, Ha Noi, VN.
Phone: (+84) 901442689 (WhatsApp)
Hotline: 02822202988
Website: lecilaser.com
Control & Repeatability | CLF | +/-5% or 200 mW/cm2, whichever is greater |
Calibration/ Radiometry (R2000) | Calibration/ Radiometry (R2000) | |
Intelli-Lamp | V 2.0 – Not compatible with older gen systems | |
High Speed Mechanical Shutter | YES (30 ms) | |
StepCure | StepCure 2.0 Can be programed on the System UI, Web UI, or loaded onto a SD card |
|
Optical | Replacement Lamp Part No. | Standard: 012-68000R Surface Cure: 012-69000R |
Optical Output | Up to 37 W/cm2 | |
Optical Filters | User Interchangeable | |
Filter Selection | No filter, 250-400 nm, 320-390 nm, 320-500 nm, 365 nm, 400-500 nm Custom Filters available | |
Warm-up period | Min 4 min | |
Lamp Technology | High Pressure 200 Watt Mercury Vapor Short Arc with integrated Intelli-Lamp | |
Lamp Life | Guaranteed 2000 hours | |
User Interface | Manual Control | Built-in PLC controller with 7 programmable PLC output channels Fully programmable in new StepCure 2.0 |
Automation / Industry 4.0 Compatibility | USB Type B | |
RJ485 Ethernet Built-in server enables Web-GUI based monitoring and remote control |
||
SD Card Store/ Read StepCure profiles, System Log, Firmware Update |
||
Flight recorder | ||
NFC | ||
Field Upgradeable system software | ||
Electrical | Rated Input Voltage | 100-240VAC, 50/60Hz |
Current | 3.5A Max at 120VAC | |
2.0A Max at 240VAC | ||
Physical | Size (H x W x D) | 268 x 139 x 289 mm (10.54 x 5.45 x 11.38 in) |
Weight | 5 kg (11 lbs) | |
Rated Operating Temperature | 15°C to 40°C | |
Warranty | System | 1 Year |
Lamp Strike | 2000 Hours |